— Articles
Apartment rooms: minimum sizes in ШНҚ 2.08.01-24
Room area, width and height requirements in one table, with clause numbers.
Room sizes are where residential projects most often go wrong. Below are the main minimum sizes from the Uzbek code ШНҚ 2.08.01-24 “Design of residential buildings”.
Rooms
| Room | Area, min | Width, min | Clause |
|---|---|---|---|
| Room in a one-room apartment | 14 m² | — | 35 |
| Living room (apartments with 2+ rooms) | 16 m² | 3.0 m | 35, 36 |
| Bedroom | 8 m² (12 m² for two) | 2.4 m | 35, 36 |
| Kitchen | 6 m² (8 m² with 2+ rooms) | 1.7 m (fittings on both sides — 2.2 m) | 35, 39 |
| Entrance hall | 4 m² | 1.4 m | 35, 40 |
| Inner corridor to living rooms | — | 1.1 m | 40 |
| Corridor to service rooms | — | 0.9 m | 40 |
| WC (with washbasin) | — | 1.6 m | 43 |
| Combined bathroom | 4 | 2.2 m | 35, 43 |
Height (cl. 38): living rooms and kitchens at least 2.7 m floor to ceiling, service rooms at least 2.4 m.
Apartments
| Rooms | 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|---|
| Area, min (m²) | 28 | 48 | 64 | 80 | 96 | 114 |
Summer rooms and unheated storage rooms are not counted in the apartment area (cl. 34, table 1).
The NORMA plugin checks these requirements in your Revit model and shows the clause for every issue.